          17. BATTERY/CHARGING SYSTEM                      DOWNTOWN 125i




 Check the continuity between the Green wire
 terminal and ground.
 There should be continuity at all times.




 Measure the resistance between each Yellow
 wire terminals.

 Standard: 0.40.6  (20C/68F)




 Disconnect the regulator/rectifier connector.

 Check for continuity between each Yellow
 wire terminal regulator/rectifier side and
 ground.
 There should be no continuity.




                                                         17-8