          16. STARTING SYSTEM                                   PEOPLE 125/150

 STARTER MOTOR CASE CONTINUITY
 CHECK
 Check to confirm that there is no continuity
 between the starter motor wire terminal and
 the motor front cover.
 Also check for the continuity between the
 wire terminal and each brush.
 Replace if necessary.




 Measure the length of the brushes.
 Service Limit: 8.5mm replace if below




 Check for continuity between the brushes. If
 there is continuity, replace with new ones.




                                                  Dust Seal
 Check if the needle bushing in the front cover
 turns freely and has no excessive play.
 Replace if necessary.
 Check the dust seal for wear or damage.




                                                  Bushing
                                                              16-4