18. STARTING SYSTEM DINK 50/125 STARTER MOTOR INSPECTION Disconnect the start motor cable ( 2) from the start MAG (1). Connect the start motor cable directly to the battery positive terminal (3). If the start motor does not turn, the starter motor is faulty. REMOVAL Remove the air cleaner (refer to the "CARBURETOR" section in the chapter 13). Turn the ignition switch turned to "OFF" Release the rubber cap (1) and remove the terminal screw (2) to disconnect the start motor cable from the start motor. Remove the two mounting bolts (3) and engine ground cable (4), then remove the start motor. 18-4