          16. BATTERY/CHARGING SYSTEM                                               People GT 125i




 CHARGING COIL WIRE

 Measure the resistance between each Yellow
 wire terminals.

 Standard: 0.4 ~ 0.6  (20C/68F)

 Disconnect the regulator/rectifier connector.
 Check for continuity between each Yellow
 wire terminal regulator/rectifier side and
 ground.
 There should be no continuity.



                                                    Regulator/Rectifier

 REMOVAL/INSTALLATION

 Remove the side body cover.
 Disconnect the regulator/rectifier connectors.
 Remove the two bolts, regulator/rectifier.
 Installation is in the reverse order of removal.




                                                     Connectors