          16. BATTERY/CHARGING SYSTEM                                                             People GT 125i



 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
 The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and
    eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and get
    prompt medical attention
 · The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
   long time, its service life will be shortened. Generally, the capacity of a battery will decrease
   after it is used for 23 years. A capacity-decreased battery will resume its voltage after it is
   recharged but its voltage decreases suddenly and then increases when a load is added.
 · When a battery is overcharged, some symptoms can be found. If there is a short circuit inside the
   battery, no voltage is produced on the battery terminals. If the rectifier won`t operate, the voltage
   will become too high and shorten the battery service life.
 · If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
   months.
 · A new battery filled with electrolyte will generate voltage within a certain time and it should be
   recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
 · Inspect the charging system according to the sequence specified in the Troubleshooting.
 · Do not disconnect and soon reconnect the power of any electrical equipment because the electronic
   parts in the regulator/rectifier will be damaged. Turn off the ignition switch before operation.
 · It is not necessary to check the MF battery electrolyte or fill with distilled water.
 · Check the load of the whole charging system.
 · Do not quick charge the battery. Quick charging should only be done in an emergency.
 · Remove the battery from the motorcycle for charging.
 · When replacing the battery, do not use a traditional battery.
 · When charging, check the voltage with an electric tester.



 SPECIFICATIONS
                              Item                                              Standard
                  Capacity                                                      12V12AH
                  Voltage          Fully charged                                  13.2V
     Battery      (20)             Insufficient charged                          < 12.3V
                  Charging current                                            1.2A* 5~10H




                                                                                               16-2