          3. INSPECTION/ADJUSTMENT                            People GT 125i



OIL FILTER REPLACEMENT
Remove the oil filler cap attaching the right-
under crankcase cover.
Place a drain pan under the crankcase.
Remove three bolts and then remove the oil filter
cap and O-ring
The spring will come out when the filter cap is
removed.
Let the engine oil drain out.
Check that the O-ring is in good condition.
Install a new oil filter.
                                                        Rubber Seal
   Make sure the rubber seal on the oil filter
        facing the left crankcase.


RESERVE TANK
COOLANT LEVEL INSPECTION
The reserve tank is under left floorboard. Check
the coolant level through the inspection window
at the left side skirt white the engine is at the
normal operating temperature, with the scooter
In an upright position.
If the coolant level is below the LOWER level
mark, remove the left floor mat, remove the lid
screw, the reserve tank lid, and then the reserve
tank cap to add coolant mixture until it reaches     Reserve Tank
the upper level mark.



 Add coolant to the reserve tank only. Do
     not attempt to add coolant by removing
     the radiator cap. Coolant in the radiator
     is under pressure and is very hot and
     can cause serious burns.




3-5