          17. IGNITION SYSTEM                                                  MXU 250R/300R


 Measure the spark plug cap resistance.
 Remove the spark plug cap and measure the
 spark plug resistance.

 Resistance: 4.25.2K/20C
 Measure the resistance in the XK range
   of the electric tester.




                                                  Ignition Coil               CDI Tester
 PERFORMANCE TEST
 Test the performance with a ignition unit
 tester.
 · Operate     the ignition unit tester by
     following       the    manufacturer`s
     instructions.
   · Use the special connector to connect
     the ignition unit.
                                                        Spark Plug     CDI Unit
 If the spark is weak, inspect the spark plug
 and ignition unit. If both of them are normal,
 replace the ignition coil with a new one.




 PULSER COIL
 INSPECTION
 Remove the front fender. (Refer to the
 chapter 2)
 Disconnect the pulser coil wire coupler and
 measure the resistance between the blue/
 yellow and green/white wire terminals.
 Resistance: 105110/20C


 Refer to the "A.C.
 GENERATOR/FLYWHEEL" section in the
 chapter 16 to remove or install.


17-7