          16. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                  MXU 250R/300R


 BATTERY                                                      Seat
 REMOVAL/INSTALLATION
 1. Make sure the ignition switch is OFF.
 2. Pull right the lock lever and pull up the
    seat at the rear.




                                                        Lock Lever




 3. Disconnect the negative (-) terminal lead
    from the battery first, then disconnect the
    positive (+) terminal lead.
 4. Remove the battery.

   When disconnecting the battery positive
   (+) cable, do not touch the frame with
   tool; otherwise it will cause short circuit
   and sparks to fire the fuel.




 INSTALLATION
 1. Installation is in the reverse order of
    removal.


   First connect the positive (+) cable and then
   negative (-) cable to avoid short circuit.


 2. Make sure the battery is installed upright
    as shown
 3. Check all bolts and other fasteners are
    secure.
 4. After installing the battery, check to see if
    the battery cables are routed correctly.




                                                            16-4