          18. STARTING SYSTEM                                              MXU 250R/300R



                                                                       Starter Relay
 STARTER RELAY
 INSPECTION
 Remove the seat. (Refer to the chapter 2)
 Turn the ignition switch ON and the starter
 relay is normal if you hear a click when the
 starter button is depressed.
 If there is no click sound:
 · Inspect the starter relay voltage
 · Inspect the starter relay ground circuit
 · Check for continuity between the starter
   relay yellow/red and green/red wire
   terminals




                                                Green/Red Wire   Yellow/Red Wire
 STARTER RELAY VOLTAGE
 INSPECTION
 Connect a 12V battery across the starter
 relay yellow/red and green/red wire
 terminals.
 Connect an electric tester between the
 starter relay large terminals and check for
 continuity between the two terminals.
 The relay is normal if there is continuity.
 Replace the starter relay with a new one if
 there is no continuity.
                                                                     Starter Relay




18-7