          5. FUEL SYSTEM                                                       MXU 250R/300R


 AIR CLEANER HOUSING                               Breather Hose
 REMOVAL/INSTALLATION

 Remove the seat (see page 2-3).
 Remove the side covers (see page 2-6).

 Remove the clip and disconnect the
 crankcase breather hose from the crankcase.
 Loosen the carburetor-to-air cleaner
 connecting tube band screw.


                                                                   Band Screw




                                               Trim Clip
 Remove the intake air duct trim clip.
 Remove the mounting bolts and then remove
 the air cleaner housing from the carburetor
 and the intake duct.

 Installation is in the reverse order of
 removal.




                                                       Bolts