          3. INSPECTION/ADJUSTMENT                                                MXU 250R/300R


 Unscrew (3) the clamp (5) and remove the
 air cleaner assembly (4) from the air cleaner
 housing.




 Remove the screw and remove the air             Screw                Air Cleaner Holder
 cleaner assembly from the air cleaner
 holder.




                                                 Air Cleaner
 Remove the air cleaner and air cleaner
 screen from the air cleaner body.
 Remove the air cleaner net from the air
 cleaner.




 Reassemble by reversing the disassembly
 sequence.
                                                 Air Cleaner screen    Air Cleaner body



3-5