mxu 300 r Manuel atelier : Page 216

Microfiches
Image preview

Page 214

Image preview

Page 215

Image preview

Page 217

Image preview

Page 218

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 347
          12. COOLING SYSTEM                                                   MXU 250R/300R


 THERMOSENSOR
 THERMOSENSOR REMOVAL
 Drain the coolant. (page 12-7)
 Disconnect the thermosensor wire.
 Remove the thermosensor from            the
 thermostat.




                                               Thermosensor   Thermosensor Connectsor



 THERMOSENSOR INSPECTION                       Thermosensor
 Suspend the thermosensor in a pan of water
 over a burner and measure the resistance
 through the sensor as the water heats up.
 Temperature() 50         80   100    120
 Resistance()  154        52   27     16




 THERMOSENSOR INSTALLATION
 Apply 3-BOND No. 1212 sealant or
 equivalent to the thermosensor threads and
 install it into the thermostat housing.
 Connect the thermosensor wire.
 Fill the radiator with coolant. (page 12-7)
 Be    sure to bleed air from the cooling
   system.




12-13