1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 347
          10.FINAL REDUCTION/
   TRANSMISSION SYSTEM                                                     MXU 250R/300R


 TOOTH CONTACT
 After backlash adjustment is carried out, the
 tooth contact must be checked. Pay attention
 to the following procedures:
  Remove the driven bevel gear.
  Clean and degrease several teeth of the
   drive and driven bevel gears.
   Apply a coating of machinist's layout dye
   or paste to several teeth of the driven bevel
   gear.
  Install the driven bevel gear.
  Rotate the driven bevel gear several turns in
   both directions.
  Remove the driven bevel gear and inspect
   the coated teeth of the drive bevel gear. The
   tooth contact pattern should be as shown in
   (1), (2) and (3).
  If tooth contact is found to be correct
   (example (2)), then to complete installation.

 (1): Incorrect (contact at tooth top)
 (2): Correct
 (3): Incorrect (contact at tooth root)

  If tooth contact is found to be incorrect
  (examples (1) and (3)), the shim thickness
  between the drive bevel gear and driven
  bevel gear must be changed and the tooth
  contact rechecked until correct.
 Make     sure to check the backlash after
   the tooth contact has been adjusted,
   since it may have changed. Adjust the
   tooth contact and backlash until they are
   both within specification. If the correct
   tooth contact cannot be maintained when
   adjusting the backlash, replace the drive
   and driven bevel gears.



 Tooth contact            Drive bevel gear shim adjustment Driven bevel gear shim adjustment
 Contact at tooth top     Increase shim thickness         Increase shim thickness
 Contact at tooth root    Decrease shim thickness         Decrease shim thickness




                                                                                    10-40