12. COOLING SYSTEM                                                          K-XCT 125i




 INSPECTION

 Suspend the thermostat in a pan of water
 over a burner and gradually raise the water
 temperature to check its operation.            Thermostat


 Technical Data
                                                                        Thermometer
    Begins to open     71 1.5°C
    Full-open          80°C
    Valve lift         3.5 mm (0.14 in)
                       minimum

  Do not let the thermostat touch the pan
    as it will give a false reading.
    Replace the thermostat if the valve
    stays open at room temperature.
   Test the thermostat after it is opened for
    about 5 minutes and holds the
    temperature at 70.




 ASSEMBLY

 Thermostat assembly is in the reverse order
 of disassembly.




                                                   Thermostat Housing




                                                                             12-20