          4. LUBRICATION SYSTEM                                                            VITALITY 50
 DISASSEMBLY
 Remove the screws and disassemble the oil
 pump.




                                                                         Bolts




                                                                  Screws
                                             Outer Rotor                     Pump Body
 INSPECTION
 Measure the pump body-to-outer rotor
 clearance.
 Service Limit: 0.25mm




                                                 Outer Rotor
 Measure the inner rotor-to-outer rotor
 clearance.
 Service Limit: 0.2mm




                                                           Inner Rotor




4-11