6. COOLING SYSTEM UXV 500 Install the water pump cover and tighten the bolts to the specified toque. Torque: 1.3 kgf-m (13 N-m, 9 lbf-ft) Water Pump Cover/O-ring Water Hose Connect the water hoses and bypass hose, then tighten the hose bands. Fill the system with recommended coolant and bleed the air (refer to the "COOLANT REPLACEMENT" section in this chapter). Bypass Hose Water Hose 6-13