          20. EVAPORATIVE EMISSION CONTROL SYSTEM                                       Downtown 300i ABS


 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
 · Do not smoke or allow flames or sparks near the working area.
 · Note the locations of tubes for proper installation.
 · Replace any damaged tube with a new one.
 · Make sure to tighten the connector of each tube securely.




 TOOLS
 · Vacuum pumpA937014
 · Pressure pump




 SPECIFICATIONS
 Purge control valve vacuum pressure         45mm/Hg
 Charcoal canister capacity                  90cc



 A. LEAKAGE TEST PIPING DIAGRAM




                                               Charcoal Canister/ Purge Control Valve
                                                                              Manifold
                                                Fuel Injector                 Absolute
                                                                Throttle Body Pressure Sensor




     Fuel Tank
                                                                                            Air Cleaner


                                                      Air By Pass Valve




 20-3