mxu 500 irs 1 Manuel atelier : Page 362

Microfiches
Image preview

Page 360

Image preview

Page 361

Image preview

Page 363

Image preview

Page 364

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 407
          17. BATTERY/CHARGING SYSTEM                    MXU 500 IRS


 Ground line

 Check the continuity between the Green wire
 terminal and ground.
 There should be continuity at all times.




 Charging coil line

 Measure the resistance between each Yellow
 wire terminals.
 Standard: 0.10.3  (20C/68F)

 Check for continuity between each Yellow
 wire terminal and ground.
 There should be no continuity.




17-9