1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 407
          11.FINAL REDUCTION/
    TRANSMISSION SYSTEM                                                   MXU 500 IRS
                                                  Primary Drive Shaft

 Remove the primary drive shaft.




                                                      Spring


 Remove the bolt/washer, then remove the
 stopper lever and spring.




                                                          Stopper Lever     Bolt/Washer




 INSPECTION

 Guide bar

 Measure the guide bar runout.
 Out of specification  Replace.

 Service Limit:
                  Less than 0.03 mm (0.0012 in)
 Do not attempt to straighten a bent guide
   bar.



11-19