1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 407
          6. COOLING SYSTEM                                                          MXU 500 IRS


 FAN MOTOR SWITCH
 REMOVAL

 Disconnect the fan motor switch connectors
 (refer to the "RADIATOR" section in this
 chapter).

 Remove the fan motor switch.




                                                        Fan Motor Switch
 INSPECTION

 Place the fan motor switch in oil contained
 in a pan as shown and raise the oil
 temperature gradually to check for the
 temperature at which the switch starts to
 operate.
 If the switch operating temperature is not
 within the specified range, replace the
 switch with a new one.
 OFFON Over 88-92°C
 ONOFF Lower 88-92°C
  Handle the cooling fan motor switch
    carefully as it is vulnerable to impact.
    Do not allow the cooling fan motor
    switch and the thermometer to
    come in contact with the bottom of the
    pan.                                       O-ring


 INSTALLATION

 Fit the O-ring.
 Tighten the cooling fan motor switch to
 specified torque.

 Torque: 1.8 kgf-m (17 N-m, 13 lbf-ft)
  Replace the O-ring a new one.
    Do not coat grease to the O-ring.

6-15