          1. GENERAL INFORMATION                                    AGILITY CITY 50 2T

 Inspection/Adjustment              Symptom               Probable Cause

 Check carburetor
 gasket for air leaks.

                                                          Carburetor not securely
                                                          tightened
                         No air leak          Air leaks   Faulty intake manifold
                                                          gasket
                                                          Deformed or broken
                                                          carburetor O-ring
 Remove auto
 bystarter connecting
 wire and check if
 bypass fuel line is
 clogged.
                                                          Broken cable
                         Not clogged          Clogged     Dirty auto bystarter
                                                          Faulty auto bystarter
 Connect auto
 bystarter wire to
 battery. Wait for 5
 minutes, then connect
 a hose to fuel
 enriching circuit and
 then blow the hose
 with mouth.              Clogged         Not Clogged     Faulty auto bystarter