          15. IGNITION SYSTEM                                                                SUPER8 125

    CDI UNIT INSPECTION
    Remove the two battery cover screws.
    Disconnect the CDI coupler and remove the
    CDI unit.
    Measure the resistance between the terminals
    using the electric tester.

· Due to the semiconductor in circuit, it is
        necessary to use a specified tester for
        accurate testing. Use of an improper
        tester in an improper range may give              CDI Unit
        false readings.                                   Green         Black/ Yellow     Black/ Red
      · Use a Sanwa Electric Tester or Kowa
        Electric Tester.
      · In this table, "Needle swings then
        returns" indicates that there is a charging
        current applied to a condenser. The needle
        will then remain at "" unless the
        condenser is discharged.
                                                 Green/
                                                 Black


                                                               Blue / Yellow     Black / Blue   Violet/Red
                                             Violet/ Black




3