15. IGNITION SYSTEM SUPER8 125 CDI UNIT INSPECTION Remove the two battery cover screws. Disconnect the CDI coupler and remove the CDI unit. Measure the resistance between the terminals using the electric tester. · Due to the semiconductor in circuit, it is necessary to use a specified tester for accurate testing. Use of an improper tester in an improper range may give CDI Unit false readings. Green Black/ Yellow Black/ Red · Use a Sanwa Electric Tester or Kowa Electric Tester. · In this table, "Needle swings then returns" indicates that there is a charging current applied to a condenser. The needle will then remain at "" unless the condenser is discharged. Green/ Black Blue / Yellow Black / Blue Violet/Red Violet/ Black 3