18. BATTERY/CHARGING SYSTEM MYROAD 700i Measure the resistance between each Yellow wire terminals. Standard: 0.10.5 (20C/68F) Check for continuity between each Yellow wire terminal of the alternator side connector and ground. There should be continuity. Replace the alternator stator if resistance is out of specification, or if any wire has continuity to ground. Alternator Connector REGULATOR/RECTIFIER Regulator/Rectifier WIRE HARNESS INSPECTION Remove the luggage box. Disconnect the regulator/rectifier connectors. Check the connectors for loose contacts of corroded terminals. Regulator/Rectifier Connectors Battery line Measure the voltage between the Red/White wire terminal and ground. There should be battery voltage at all times. Regulator/Rectifier Connector 18-8