1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 181
          9. DRIVE AND DRIVEN PULLEYS/
   KICK STARTER                                         AGILITY CITY 50
                                                    Movable Drive Face
 INSTALLATION
 Install the drive pulley collar and movable
 drive face onto the crankshaft.




                                                                    Drive Pulley Collar


 Set the drive belt on the drive pulley collar.
 Install the drive pulley face and tighten the
 drive face nut. ( 9-6)
 Torque: 5.5~6.5kgf-m
 Do not get oil or grease on the drive belt
    or pulley faces.




 STARTER PINION
 REMOVAL
 Remove the left crankcase cover.
 Remove the drive pulley.
 Remove the starter pinion holder.
 Remove the starter pinion.

 INSPECTION
 Inspect the starter pinion shaft forcing part
 for wear or damage.
 Inspect the starter pinion for smooth                            Starter Pinion
 operation.                                                    Starter Pinion Shaft
 Inspect the starter pinion and shaft for wear
 or damage.

 INSTALLATION
 Apply a small amount of grease to the starter
 pinion shaft and install it in the reverse order
 of removal.