          19. LIGHTS/INSTRUMENT/SWITCHES/HORN                            STRYKER 125/150




 INSPECTION
 Check the fuel unit O-ring for wear,
 damage or deformation. Replace if
 necessary.
 Measure the resistances between the fuel
 unit wire terminals with the float at the
 upper (Full) and lower (Empty) positions.
 Resistances: Upper (Full): 925
                Lower (Empty): 70100
 Connect the fuel unit wire coupler to the
 wire harness and turn the ignition switch
 ON. Check the fuel gauge needle for              Empty                    Full
 correct indication by moving the float up
 and down.
 If the needle does not move to "F" or "E",
 the fuel gauge is faulty and replace it with a
 new one.
 If the needle swings, the fuel unit is faulty
 and replace it with a new one.



 INSTALLATION
 Install the fuel unit in the reverse of
 removal.

   Check for fuel leakage after installation.




                                                  Fuel Gauge




                                                                       19-8