          17. CHARGING SYSTEM                                                 STRYKER 125/150


 TESTING RANGE
 Use the xK range for the Sanwa                                                  Unit: K
 Tester.                            (+)Probe
 Use the x100 range for the Kowa               Pink   Yellow     Red     Green    Black
                                   (-)Probe
 Tester.
                                     Pink                       4-7K                

                                   Yellow                       4-7K                

                                      Red                                           

                                    Green      4-6K    4-6K    13-17K              1-2K

                                    Black      4-7K    4-7K    13-17K    1-2K

                                   Note: The readings in this table are taken with a Kowa
                                         Tester.




17-7