          11. FUEL SYSTEM                                                            STRYKER 125/150


 CARBURETOR REMOVAL                              Auto Bystarter Wire
 Remove the frame body cover.
 Disconnect the auto bystarter wire connector.




 Loosen the drain screw and drain the fuel
 from the float chamber.
 Disconnect the fuel tube and vacuum tube
 at the carburetor.




                                                 Fuel Tube




 Loosen the throttle cable adjusting nut and     Air Cleaner Connecting Tube Band     Adjusting Nut
 lock nut, and disconnect the throttle cable
 from the carburetor.
 Loosen the carburetor intake manifold band
 and air cleaner connecting tube band screws
 and then remove the carburetor.




                                                 Lock Nut         Throttle Cable Intake Manifold Band