people 250 Manuel atelier : Page 149

Microfiches
Image preview

Page 147

Image preview

Page 148

Image preview

Page 150

Image preview

Page 151

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 229
          12. COOLING SYSTEM                                                      PEOPLE 250


  THERMOSTAT INSPECTION
  Suspend the thermostat in a pan of water
  over a burner and gradually raise the water
  temperature to check its operation.             Thermostat
  Technical Data
                                                                          Thermometer
    Begins to open             802
    Full-open                    90
    Valve lift               3.54.5mm




                                                               O-ring
 · Do not let the thermostat touch the pan
      as it will give a false reading.
    · Replace the thermostat if the valve
      stays open at room temperature.
    ·Test the thermostat after it is opened for
      about 5 minutes and holds the
      temperature at 70.

  THERMOSTAT INSTALLATION
  The installation sequence is the reverse of
  removal.
 Replace the O-ring with a new one and
    apply grease to it.                               Thermosensor



  Fill the cooling system with the specified
  coolant. ( 3-9)




                                                                               12-16