19. STARTER SYSTEM                                MXU 500 IRS

                                                 Starter MAG
 CONTINUTY INSPECTION

 Disconnect the starter MAG switch connector
 and cables.
 Connect a fully charged 12 V battery positive
 wire to the relay switch Yellow/Red wire
 terminal and negative wire to the
 Yellow/Green wire terminal.

 There should be continuity between the cable
 terminals while the battery is connected, and
 no continuity when the battery is
 disconnected.




19-5