          16. IGNITION SYSTEM                                                                            ATV 50

 IGNITION CIRCUIT (MXU 50 REVERSE)




 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
 · Check the ignition system according to the sequence specified in the Troubleshooting.
 · The ignition system adopts CDI unit , change gear control and the ignition timing cannot be
   adjusted.
 · If the timing is incorrect, inspect the CDI unit, A.C. generator, change gear control and replace
   any faulty parts. Inspect the CDI unit with a CDI tester
 · Loose connector and poor wire connection are the main causes of faulty ignition system. Check
   each connector before operation.
 · Use of spark plug with improper heat range is the main cause of poor engine performance.
 · The inspections in this section are focused on maximum voltage. The inspection of ignition coil
   resistance is also described in this section.
 · Inspect the ignition switch according to the continuity table specified in page 18-6.
 · Inspect the spark plug referring to Section 3.