          15. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                                  ATV 50

                                                  REC/REG Connector       A.C.G Connector
 A.C.GENERATOR INSPECTION
 (MXU 50REVERSE/MXU 50)

 Disconnect the A.C.Generator connector.
 Measure the resistance between the yellow
 wire terminals of the alternator side
 connector.

 Standard: 0.1-1  (20°C/68°F)

 Check for continuity between each yellow
 wire terminal of the alternator side
 connector and ground.                                     Rectifier/Regulator
 There should be no continuity.

 Replace the alternator stator if resistance is
 out of specification, or if any wire has
 continuity to ground.

 REGULATOR/RECTIFIER
 Wire harness inspection

 Disconnect the regulator/rectifier connector.
 Check the connector for loose contacts or
 corroded terminals.

 Battery line
 Measure the voltage between the red wire
 terminal and ground.
 There should be battery voltage at all times.

 Ground line
 Check the continuity between the green
 wire terminal and ground.
 There should be continuity at all times.

 Voltage feedback line
 Measure the voltage between the black wire
 terminal and ground.
 There should be battery voltage with the
 ignition switch "ON" , and no voltage with
 the ignition switch "OFF".




15-9