          15. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                        ATV 50



    When measuring current using a
    tester, set it to a high range, and then
    bring the range down to an
    appropriate level. current flow higher
    than the range selected may blow out
    the fuse in the tester.
    While measuring current, do not turn
    the ignition switch "ON".A sudden
    surge of current may blow out the
    fuse in the tester.



 Specified current leakage: 1 maximum


 If current leakage exceeds the specified
 value, a shorted circuit is likely.
 Locate the short by disconnecting
 connections one by one and measuring the
 current.




 A.C. GENERATOR INSPECTION
 (MX'ER 50)
                                               A.C. Generator Connector

   Inspect with the engine installed.

 Disconnect the A.C. generator connector.
 Measure the resistances between the
 charging coil terminals (white­green) and
 lighting coil terminals (yellow­green).
 Resistances:
 Charging coil White­green 0.21.2
 Lighting coil Yellow­     0.31.0
               green

 Refer to 8-3 for A.C. generator removal.