          15. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                               ATV 50


 TORQUE VALUES
 Regulator/Rectifier lock nut   0.9 kgf-m (9 N-m, 6.5 lbf-ft)




 TESTING INSTRUMENTS
 Kowa electric tester
 Sanwa electric tester


 TROUBLESHOOTING
 No power                               Intermittent power
 · Dead battery                         · Loose battery cable connection
 · Disconnected battery cable           · Loose charging system connection
 · Fuse burned out                      · Loose connection or short circuit in
 · Faulty ignition switch                 lighting system

 Low power                              Charging system failure
 · Weak battery                         · Loose, broken or shorted wire or connector
 · Loose battery connection             · Faulty regulator/rectifier
 · Charging system failure              · Faulty A.C. generator
 · Faulty regulator/rectifier




                                                                                 15-4