          15. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                                               ATV 50


 SERVICE INFORMATIONN
 GENERAL INSTRUCTIONS
   The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and
   eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and get
   prompt medical attention

 · The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
   long time, its service life will be shortened. Generally, the capacity of a battery will decrease
   after it is used for 23 years. A capacity-decreased battery will resume its voltage after it is
   recharged but its voltage decreases suddenly and then increases when a load is added.
 · When a battery is overcharged, some symptoms can be found. If there is a short circuit inside the
   battery, no voltage is produced on the battery terminals. If the rectifier won`t operate, the voltage
   will become too high and shorten the battery service life.
 · If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
   months.
 · A new battery filled with electrolyte will generate voltage within a certain time and it should be
   recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
 · Inspect the charging system according to the sequence specified in the Troubleshooting.
 · Do not disconnect and soon reconnect the power of any electrical equipment because the electronic
   parts in the regulator/rectifier will be damaged. Turn off the ignition switch before operation.
 · It is not necessary to check the MF battery electrolyte or fill with distilled water.
 · Check the load of the whole charging system.
 · Do not quick charge the battery. Quick charging should only be done in an emergency.
 · Remove the battery from the motorcycle for charging.
 · When replacing the battery, do not use a traditional battery.
 · When charging, check the voltage with an voltmeter.
 SPECIFICATIONS
                                    Item                                             Standard
                                      MX'ER 50                          12V-4AH
                    Capacity/Model
                                      MXU 50 REVERSE/MXU 50             12V-8AH
                    Voltage           Fully charged                     13.1V
 Battery            (20)              Undercharged                      12.3V
                    Charging current                                    STD: 0.4A Quick: 4A
                    Charging time                                       STD: 510hr Quick: 30min
                    Capacity                                            150W
 A.C. Generator
                    Charging coil resistance (20)                       0.21.5 




15-3