          4. LUBRICATION SYSTEM                                                            MXU 250R/300R


 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
 · The maintenance of lubrication system can be performed with the engine installed in the frame.
 · Use care when removing and installing the oil pump not to allow dust and foreign matters to
   enter the engine and oil line.
 · Do not attempt to disassemble the oil pump. The oil pump must be replaced as a set when it
   reaches its service limit.
 · After the oil pump is installed, check each part for oil leaks.


 SPECIFICATIONS                                                                      Unit: mm (in)

                      Item                                   Standard              Service Limit
            Inner rotor-to-outer rotor clearance   0.15 (0.006)                    0.2 (0.008)
 Oil pump Outer rotor-to-pump body clearance 0.150.2 (0.0060.008)                  0.25 (0.01)
            Rotor end-to-pump body clearance       0.040.09 (0.00160.0036) 0.12 (0.0048)


 TROUBLESHOOTING
 Oil level too low                                     Poor lubrication pressure
 · Natural oil consumption                             · Oil level too low
 · Oil leaks                                           · Clogged oil filter or oil passages
 · Worn or poorly installed piston rings               · Not use the specified oil
 · Worn valve guide or seal




                                                                                                 4-2