          18. STARTING SYSTEM                                           MXU 250R/300R


                                                               Recoil Starter
 RECOIL STARTER

 Refer to the chapter 9 to remove recoil
 starter.
 Do not disassembly that the recoil starter
    would not be assembly.




 ROPE REPLACE
 Insert the rope into the hook part of the
 friction plate, reel the rope clockwise five
 times with the rope, then cut the rope.




                                                Rope




                                                       Plug
 Hook the rope onto the groove of the recoil
 starter case.

 Remove the plug of the recoil starter grip.