          15. IGNITION SYSTEM                              Mongoose/KXR 90/50

 IGNITION COIL
 REMOVAL
 Remove the spark plug cap.
 Disconnect the ignition coil wires and
 remove the ignition coil bolt and ignition
 coil.




                                                         Ignition Coil




 INSPECTION
 CONTINUITY TEST
 The CDI unit is not adjustable.      If the
    timing is incorrect, inspect the CDI unit,
    pulser coil and A.C. generator and
    replace any faulty parts.

 Measure the resistance between the ignition
 coil primary coil terminals.
 Resistance:
 Mongoose/KXR 90) : 2.22.6/20°C
 Mongoose/KXR 50) : 3.715.2/20°C

 Measure the secondary coil resistances with
 and without the spark plug cap.
 Resistances:
 (Mongoose/KXR 90)
   (with plug cap) : 8.39K/20°C
   (without plug cap) : 3.14K/20°C
 Mongoose/KXR 50)
   (with plug cap) : 8.81K/20°C
   (without plug cap) : 3.51K/20°C

 Correctly operate the tester following the
    manufacturer`s instructions.


 Note: The readings in this table are taken
       with a YF-3501 Tester.