1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 246
          14. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                      Mongoose/KXR 90/50

                                                                         Bolts
 BATTERY REMOVAL
 Remove seat. (See page 2-3)
 Remove the battery cover, by removing the
 mount bolts. (Make sure the ignition switch
 is OFF)
 Remove the battery by removing the bolts.




                                                                    Battery Cover

                                                   Negative (-) Cable        Positive (+) Cable
 First disconnect the battery negative (-)
 cable and then the positive (+) cable.
   When disconnecting the battery positive
   (+) cable, do not touch the frame with
   tool; otherwise it will cause short circuit
   and sparks to fire the fuel.

 The installation sequence is the reverse of
 removal.
   First connect the positive (+) cable and then
   negative (-) cable to avoid short circuit.




 BATTERY VOLTAGE (OPEN CIRCUIT
 VOLTAGE) INSPECTION
 Remove the seat. (See page 2-3)
 Disconnect the battery cables.
 Measure the voltage between the battery
 terminals.
 Fully charged : 13.1V
 Undercharged : 12.3V max
 Battery charging inspection must be
   performed with a voltmeter.




                                                                                            14-4