19. STARTING SYSTEM K-XCT 125i STARTER MOTOR INSPECTION Disconnect the starter motor cable from the start relay. Connect the start motor cable directly to the battery positive terminal. If the starter motor fail to work, the starter motor is faulty. (1) REMOVAL Turn the ignition switch turned to "OFF" position. Release the rubber cap (1) and remove the terminal screw (2) to disconnect the start motor cable from the start motor. (2) Remove two mounting bolts (3) , then remove the start motor. (3) 19-3