10. A.C. GENERATOR/STARTER CLUTCH                                                        K-XCT 125i



 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
  All servicing operations and inspections in this section can be made with the engine installed.
  Drain the coolant before removing the right crankcase cover.
  Be careful not to drain the coolant when the engine temperature is high. (Perform this operation
  when the engine is cold.)
  Drain the coolant into a clean container.
  Drain the engine oil into a clean container before removing the right crankcase cover.
  When the right crankcase cover is installed, fill with the recommended engine oil and coolant.
  Then, bleed air from the water jacket.



 SPECIFICATIONS
 Engine oil: SAE 15W/40#
             API-SJ
 Oil capacity at change: 1.0 L
 Coolant: distilled water + coolant concentrate
 Coolant capacity: 0.87L


 SPECIAL TOOLS
 Flywheel puller            A120E00003
 Flywheel holder            A120E00021




 TORQUE VALUES
 Flywheel nut : 5.0~6.0 kgf-m


 TROUBLESHOOTING


 Starter motor rotates but engine fail to start
  Faulty starter clutch
  Starter motor rotates reversely
  Weak battery




                                                                                           10-2